      STF-C Thermostatic Bellows Steam Trap

      Product overview

      Product model: STF-C
      Nominal diameter: DN15~100mm
      Nominal pressure: PN0.05-1.6MPa
      Main material: forged steel, stainless steel, titanium alloy steel, chromium molybdenum steel, low temperature steel
      Drive mode: manual
      Design specification: GB/T 9093
      Structure length: GB/T 12250
      Threaded connection: ISO 228
      Flanged connection: JB/T 79,GB 9113,ANSI B16.34
      Test and inspection: GB/T 13927

      STF-C Thermostatic Bellows Steam Trap product details

      Structural characteristics of STF-C Thermostatic Bellows Steam Trap

       1, the drainage temperature can be adjusted between 70-100 degrees, easy to use. 
       2, to prevent the discharge of high temperature condensate water, to maintain the steam pipeline heat. 
       3, continuous emissions, no noise. Small fluctuations in steam pressure have no effect on use. 
       4, simple structure, easy installation, free. 
       5, by increasing the diameter of the corrugated pipe to increase the amount of condensate arrangement. 
       6, with good emptying performance, not afraid of freezing. Zero leakage, back pressure rate of 75% or more.


      STF-C Thermostatic Bellows Steam Trap main technical parameters

      Product number Nominal diameter Connection method use pressure The maximum
      allowable
      temperature
      Dimensions reference weight
      L H1 H2 W
      YSF-A 15-20 
             25
      Thread 0.05-1.6 220 125
             130
          45 
             48
      1.2
      YSF-A 32-50 Thread 0.05-1.6 220 150     55 
             64 
             73
      2
      YSF-B 15-25 Flange 0.05-1.6 220 140     95 
             105
             115
      3.4
      YSF-B 32-50 Flange 0.05-1.6 220 160     135
             145
             160
      6.5
      YTF-A-16C 15-20 
             25
      Thread 0.05-1.6 220 155 40 75 45 1.6
      32-50 195 55 100 78 3.4
      STF-B-16C 15-20 
             25
      Thread 0.05-1.6 220 95 
             105
      110 30 55 2.8
      32-40 
             50
      110
             120
      155 40 60 4.2
      STF-C-16C 15-20 
             25 
             32-50
      Flange 0.05-1.6 220 150
             160
             230
      180 50 55 
             120

             13
      65-80 
             100
      360
             310
      210 70 150 26


      STF-C Thermostatic Bellows Steam Trap drainage

      Model / Size Steam trap working pressure (△ t) .kg / cm2
      CS14 / STB / STC 0.5 1 2 4 6 8 10 12 16
      △ t35 500 780 800 900 950 980 1000 1050 1100
      △ t25 300 400 460 500 540 700 780 800 860
      △ t15 180 200 250 280 310 350 400 450 520


      Note: 
       1, △ t for the difference between the discharge temperature and saturated condensate temperature, the temperature (△ t) increases, the displacement increases. 
       2, the valve factory hydrophobic temperature has been adjusted at 95 or so, if you want to change the hydrophobic temperature or displacement, the valve can be adjusted to rotate the top of the screw. Turn the spool clockwise to reduce the amount of hydrophobic and reduce the hydrophobic temperature. When the valve is rotated counterclockwise and the spool is retracted, the hydrophobic amount increases and the hydrophobic temperature increases. Tighten the lock nut after adjustment. 
       3, the pressure difference is the pressure difference between the inlet and outlet of the trap, displacement refers to the amount of steam condensate discharged continuously in a unit hour.



      Reminder:

      All text, data and pictures in this article are for reference only.To see more details of the STF-C Thermostatic Bellows Steam Trap performance parameters, structural dimension parameters, pricing, etc., or to request high quality printing samples, please Contact us.

      +86-021-57278881
      qrCode
      <bdo id="m8sa2"><input id="m8sa2"></input></bdo>
      • <samp id="m8sa2"><tfoot id="m8sa2"></tfoot></samp>
        <strike id="m8sa2"><menu id="m8sa2"></menu></strike>
        <samp id="m8sa2"><tfoot id="m8sa2"></tfoot></samp>
        • <ul id="m8sa2"></ul>
        • <samp id="m8sa2"><tbody id="m8sa2"></tbody></samp>
        • <ul id="m8sa2"></ul><samp id="m8sa2"><tfoot id="m8sa2"></tfoot></samp><blockquote id="m8sa2"><tfoot id="m8sa2"></tfoot></blockquote>
          <samp id="m8sa2"></samp>